
Geotextile Product Data- Huesker Inc.
___________________________________________________________________________
|Property |Comtrac |Comtrac |Comtrac |Comtrac |Comtrac |
|___________________|__________|__________|___________|__________|__________|
|Mass Per Unit |6G/185 |60.006 |270.270 |450.140 |750.285 |
|g/m2 (oz/yd2) | | | | | |
|___________________|__________|__________|___________|__________|__________|
|Structure |W |W |W |W |W |
|___________________|__________|__________|___________|__________|__________|
|Polymer |PP |PP |PET |PET |PET |
|Composition | | | | | |
|___________________|__________|__________|___________|__________|__________|
|% Open Area |<1 |<1 |<1 |<1 |<1 | |CWO-22125 | | | | | | |___________________|__________|__________|___________|__________|__________| |AOS |(50-70) |(40-70) |0.4(40) |0.4(40) |0.4(40) | |ASTM D4491-87 | | | | | | |mm (U.S. Seive) | | | | | | |___________________|__________|__________|___________|__________|__________| |Permittivity |(0.1) |(0.1) |(0.2) |(0.2) |(0.2) | |ASTM D4491-92 | | | | | | |sec-1/Flow Rate | | | | | | |l/min/m2 | | | | | | |(gal/min/ft2) | | | | | | |___________________|__________|__________|___________|__________|__________| |Puncture |0.40 |0.53 |2.0 |2.0 |2.& | |ASTM D 4833-88 |(90) |(120) |(460) |(460) |(600) | |kN (lb) | | | | | | |___________________|__________|__________|___________|__________|__________| |Mullen |2756 |4134 |10335 |10335 |11700 | |Burst |(500) |(600) |(1500) |(1500) |(1700) | |ASTM D 3786-87 | | | | | | |kPa (psi) | | | | | | |___________________|__________|__________|___________|__________|__________| |Trapezoid |NA |NA |(600) |(600) |(700) | |Tear Strength | | | | | | |ASTM D 4533-91 | | | | | | |kN (lb) | | | | | | |___________________|__________|__________|___________|__________|__________| |Grab/Tensile |NA |NA |NA |NA |NA | |Elongation | | | | | | |ASTM D 4632-91 | | | | | | |kN (lb)% | | | | | | |___________________|__________|__________|___________|__________|__________| |Wide With | | | | | | |Tensile Elongation | | | | | | |ASTM D 4595-86 | | | | | | |kN/m (lb/in) | | | | | | |MD |35 |80 |270 |450 |750 | | |(200)/13 |(400)/13 |(1500)/11 |(2500)/11 |(4200)/11 | |XD |35 |80 |270 |140 |285 | | |(200)/13 |(400)/13 |(1500)/11 |(800)/11 |(1600)/11 | |___________________|__________|__________|___________|__________|__________| |Manufacturer's |R |R |R |R |R | |Suggested | | | | | | |Applications | | | | | | |___________________|__________|__________|___________|__________|__________| W="Woven" D="Drainage" NW="Nonwoven" P="Protection" O/C="Other" or combination E="Erosion" Control Pet="Polyester" A/O="Asphalt" Overlay PP="Polypropylene" S/F="Silt" Fence PE="Polythylene" NA="Manufacturer" determined that S/S="Separation/stabilization" this data was not appilicable R="Reinforcement" to the product or the data was F="Filtration" unavailable NP="Data" not provided by manufacturer